Skip to product information
1 of 3

River Medical

GE Corometrics 170 Series

GE Corometrics 170 Series

Regular price $590.00
Regular price Sale price $590.00
Sale Sold out
Tax included.
Condition

GE Corometrics 170 Series Fetal Monitors Features

The GE Corometrics 170 Series is a fetal monitor that can be used in both medical offices and hospitals. The 170 Series Fetal Monitor is a lightweight monitor that can effectively and accurately monitor both the mother and baby at the same time. This offers a non-invasive way of tracking the baby's heart rate. At the same time, the monitor comes with a 9-crystal Pulsed Doppler Ultrasound technology that comes with a wide beam to help detect the fetal heart rate. Along with monitoring TOCO and fetal movement with high and low heart rate alarms. The Corometrics 170 is a monitor for a single baby whereas the Corometrics 172 is used for twins. The GE Corometrics 170 has a larger easy read LED Display screen, that makes it easier to read at a distance.

 

 

  • Alerts you to fetal heart rate concerns - The fetal heart rate alarm provides both audible and visual alerts if the heart rate is higher or lower than the range you set as normal
  • Helps you place the transducer - Independent volume controls make it easier to locate the transducer for the most effective monitoring
  • Can monitor multiple heart rates - There is an option to monitor twins
  • Displays important information prominently - The large, easy-to-read LCD clearly presents information about fetal heart rate and uterine activity
  • Offers portability - An optional mobile roll stand cart lets you transport the monitor and all of its necessary accessories

Models of the 170 Series

  • Model 171 - The Model 171 Antepartum Fetal Monitor provides singleton ultrasound and external uterine activity monitoring.
  • Model 172 - The Model 172 Antepartum Fetal Monitor provides dual ultrasound and external uterine activity monitoring.
  • Model 173 - The Model 173 Intrapartum Monitor provides dual heart rate monitoring using FECG and ultrasound. The monitor also provides external uterine activity monitoring using a toco transducer or internal monitoring using an intrauterine pressure catheter (IUPC).
  • Model 174 - The Model 174 Intrapartum Monitor provides dual heart rate monitoring using FECG/ultrasound or dual ultrasound. The monitor also provides external uterine activity monitoring using a toco transducer or internal monitoring using an IUPC.

 

GE Corometrics 170 Series Fetal Monitors Specifications

 

Dimensions

  • Height: 5.75 in (14.6 cm)
  • Width: 16.75 in (42.5 cm)
  • Depth: 10 in (25.4 cm),/li>
  • Weight: 8 lb (3.6kg),//li>

Environmental Operating Conditions

  • Ambient Temperature: 50°F to 104°F (10°C to 40°C)
  • relative Humidity: 10% to 75%, non-condensing

Environmental Storage Conditions

  • Ambient Temperature: 14°F to 131°F (–10°C to 55°C)
  • Relative Humidity: 10% to 90%, non-condensing

Power Requirements

  • Nominal line voltage: 100-230 VAC
  • Line frequency: 50/60 Hz (operates over 47-63 Hz)
  • Power consumption: ≤30 VA
  • Monitor DC input: 12 Vdc at 2.5A

Operating Specifications

  • Technique Pulsed Doppler with autocorrelation processing
  • Transducer Type 9-crystal
  • Pulse Repetition 2 kHz (all modes)
  • Frequency Pulse Duration 92 μs
  • Transmitter Frequency 1.151 MHz
  • Spatial-Average Temporal Isata <5 mW/cm2
  • Average Intensity
  • Focal 20 dB Beam Area 16.6 cm2, at a range = 7 cm
  • Peak Instantaneous 1.8 mW/cm2
  • Intensity
  • Heart Rate Counting Range 50-210 BPM
  • Leakage Current Complies with IEC 60 1.1 and/or IEC 601.1.1 harmonized national standard; Complies with EN 60601-1-2:2002

FECG Mode

  • Technique: Peak detecting, beat-to-beat cardiotachometer
  • Heart range counting range: 30-240 BPM
  • Heart rate resolution: 1 BPM
  • Artifact elimination: service selectable, ±25 BPM artifact rejection
  • Countable input signal range: 15µV to 2mV peak-to-peak
  • Offset voltage tolerance (differential): ±300 mVdc maximum
  • Maximum common mode voltage: 20V peak-to-peak
  • Common mode rejection: Balanced: >120 dB at mains frequency, with patient cable, Unbalanced 5kΩRA or LA: >110 dB at mains frequency
  • Input impedance: Differential: >10MΩ; Common mode: >20MΩ
  • Mains frequency rejection: >40 dB
  • Leakage current: complies with IEC 601.1 and/or IEC 601.1.1 harmonized national standard
  • Isolation, mains-to-patient: >5656 Vdc

Ultrasound Mode

  • Technique: pulsed Doppler with autocorrelation processing
  • Transfer transducer type: 9-crystal
  • Pulse repetition frequency: 2 kHz (all modes)
  • Pulse duration: 92 µs
  • Transmitter frequency: 1.151 MHz
  • Spatial-Average temporal average intensity: Isata<5 mW/ cm²
  • Focal 20 dB beam area: 16.6 cm², at a range = 7 cm
  • Peak instantaneous intensity: 1.8 mW/cm²
  • Heart rate counting range: 50-210 BPM
  • Leakage current: complies with IEC 601.1 and/or IEC 601.1.1 harmonized national standard

 

View full details